Electric Analysis

Click on the exercise number to move on to the example page

The values mentioned in Notes are based on Femtet 32-bit edition with the following system.
CPU: Intel Core i7-3770 3.40GHz Memory: 4.00GB
The values in Notes may vary depending on the version of Femtet and system.

Electric Analysis

1

Parallel-Plate Air-Gap Capacitor

Setup Condition and Analysis Type

Static analysis (dielectric material)
Open boundary(Absorbing boundary)
Voltage specified

Notes

  • The Number of Meshes 6755
  • Analysis Time 2sec
  • Maximum Memory Usage 56MB

2

Parallel-Plate Dielectric Capacitor

Setup Condition and Analysis Type

Static analysis (dielectric material)
Open boundary(Absorbing boundary)
Voltage specified

Notes

  • The Number of Meshes 10716
  • Analysis Time 3sec
  • Maximum Memory Usage 56MB

3

Capacitances across Multiple Electrodes

Setup Condition and Analysis Type

Static analysis (dielectric material)
Open boundary(Absorbing boundary)
Voltage specified

Notes

  • The Number of Meshes 9820
  • Analysis Time 3sec
  • Maximum Memory Usage 57MB

4

Floating Electrode’s Potential

Setup Condition and Analysis Type

Static analysis (dielectric material)
Open boundary(Absorbing boundary)
Voltage specified
Floating electrode

Notes

  • The Number of Meshes 15693
  • Analysis Time 3sec
  • Maximum Memory Usage 57MB

5

Electric Field Created by Point Charge

Setup Condition and Analysis Type

Static analysis (dielectric material)
Open boundary(Absorbing boundary)
Charge amount

Notes

  • The Number of Meshes 6781
  • Analysis Time 1sec
  • Maximum Memory Usage 71MB

6

Electric Field Created by Spherical Charge

Setup Condition and Analysis Type

Static analysis (dielectric material)
Open boundary(Absorbing boundary)
Charge density

Notes

  • The Number of Meshes 7629
  • Analysis Time 2sec
  • Maximum Memory Usage 72MB

7

Electrostatic Forces Applied on Dielectric Material

Setup Condition and Analysis Type

Static analysis (dielectric material)
Open boundary(Absorbing boundary)
Voltage specified

Notes

  • The Number of Meshes 7631
  • Analysis Time 2sec
  • Maximum Memory Usage 71MB

8

Electroplating(Hull Cell Test Bath)

Setup Condition and Analysis Type

Static analysis (conductor)
Plating analysis
Plating wall

Notes

  • The Number of Meshes 857
  • Analysis Time 3sec
  • Maximum Memory Usage 125MB

9

Plating Analysis(Plating a Device in the Bath)

Setup Condition and Analysis Type

Static analysis (conductor)
Plating analysis
Plating wall

Notes

  • The Number of Meshes 41512
  • Analysis Time 2min 51sec
  • Maximum Memory Usage 470MB

10

Hall Element Analysis

Setup Condition and Analysis Type

Static analysis (conductor)
Hall element analysis Options
External magnetic field
Voltage specified
Floating electrode

Notes

  • The Number of Meshes 926/2785
  • Analysis Time 3sec/4sec
  • Maximum Memory Usage 348MB/336MB

11

Conductor’s Resistance

Setup Condition and Analysis Type

Static analysis (conductor)
Voltage specified

Notes

  • The Number of Meshes 744
  • Analysis Time 0sec
  • Maximum Memory Usage 71MB

12

Periodic Boundary Condition

Setup Condition and Analysis Type

Static analysis (dielectric material)
Periodic boundary
Voltage specified

Notes

  • The Number of Meshes 1110
  • Analysis Time 0sec
  • Maximum Memory Usage 71MB

13

Anisotropic Dielectric Material

Setup Condition and Analysis Type

Static analysis (dielectric material)
Anisotropic permittivity
Voltage specified

Notes

  • The Number of Meshes 4618
  • Analysis Time 1sec
  • Maximum Memory Usage 71MB

14

Harmonic Analysis of Conductor in the Air

Setup Condition and Analysis Type

Harmonic analysis
Voltage Specified

Notes

  • The Number of Meshes 10619
  • Analysis Time 3sec
  • Maximum Memory Usage 933MB

15

Uneven Electric Field

Setup Condition and Analysis Type

Static analysis (dielectric material)
Voltage specified

Notes

  • The Number of Meshes 56786
  • Analysis Time 8sec
  • Maximum Memory Usage 114MB

16

Anisotropic Conductor

Setup Condition and Analysis Type

Static analysis (dielectric material)
Anisotropic conductivity
Voltage specified

Notes

  • The Number of Meshes 4618
  • Analysis Time 1sec
  • Maximum Memory Usage 71MB

17

Floating Capacitance

Setup Condition and Analysis Type

Static analysis (dielectric material)
Voltage specified
I/O Port

Notes

  • The Number of Meshes 31424
  • Analysis Time 9sec
  • Maximum Memory Usage 102MB

18

Electric Resistance Set on Boundary Face

Setup Condition and Analysis Type

Static Analysis (Resistance)
Electric Resistance Boundary

Notes

  • The Number of Meshes 2405
  • Analysis Time 1sec
  • Maximum Memory Usage 119MB

Stress Analysis・Electric Analysis

Back to Product