Electromagnetic Analysis

Click on the exercise number to move on to the example page

The values mentioned in Notes are based on Femtet 32-bit edition with the following system.
CPU: Intel Core i7-3770 3.40GHz Memory: 4.00GB
The values in Notes may vary depending on the version of Femtet and system.

Electromagnetic Analysis

1

Waveguide Filter Loaded with Dielectric Material

Setup Condition and Analysis Type

Harmonic analysis
I/O Port
Electric wall

Notes

  • The Number of Meshes 643
  • Analysis Time 12sec
  • Maximum Memory Usage 85MB

2

Circulator

Setup Condition and Analysis Type

Harmonic analysis
Fast sweep
Static Magnetic Field
Tensor permeability
I/O Port

Notes

  • The Number of Meshes 6549
  • Analysis Time 2min
  • Maximum Memory Usage 523MB

3

Antenna with Impedance-Matching Components

Setup Condition and Analysis Type

Harmonic analysis



Fast sweep
Open boundary
Internal port
Lumped constant

Notes

  • The Number of Meshes 11069
  • Analysis Time 51sec
  • Maximum Memory Usage 616MB

4

Horn Antenna

Setup Condition and Analysis Type

Harmonic analysis
I/O Port
Open boundary

Notes

  • The Number of Meshes 7874
  • Analysis Time 15sec
  • Maximum Memory Usage 312MB

5

Cavity Resonator

Setup Condition and Analysis Type

Harmonic analysis
Fast sweep
I/O Port
Adaptive mesh

Notes

  • The Number of Meshes 6576
  • Analysis Time 26sec
  • Maximum Memory Usage 187MB

6

Patch Antenna

Setup Condition and Analysis Type

Harmonic analysis
Fast sweep
Internal port
Open boundary
Electric wall
Adaptive mesh

Notes

  • The Number of Meshes 7151
  • Analysis Time 47sec
  • Maximum Memory Usage 322MB

7

Dipole Antenna

Setup Condition and Analysis Type

Harmonic analysis
Open boundary (PML)
Internal port

Notes

  • The Number of Meshes 84069
  • Analysis Time 1min20sec
  • Maximum Memory Usage 782MB

8

Open Stub

Setup Condition and Analysis Type

Harmonic analysis
Fast sweep

Notes

  • The Number of Meshes 15830
  • Analysis Time 1min 49sec
  • Maximum Memory Usage 726MB

9

Coplanar Waveguide with Bend

Setup Condition and Analysis Type

Harmonic analysis
Coplanar waveguide

Notes

  • The Number of Meshes 15007
  • Analysis Time 1min 10sec
  • Maximum Memory Usage 526MB

10

Coil Formed in a Substrate

Setup Condition and Analysis Type

Harmonic analysis
Strip line

Notes

  • The Number of Meshes 5260
  • Analysis Time 23sec
  • Maximum Memory Usage 193MB

11

TE-Mode Dielectric Resonator(3D)

Setup Condition and Analysis Type

Resonant analysis
Conductor Wall

Notes

  • The Number of Meshes 2580
  • Analysis Time 14sec
  • Maximum Memory Usage 95MB

12

TE-Mode Dielectric Resonator (2D)

Setup Condition and Analysis Type

Resonant analysis
Axisymmetric model
Electric wall (symmetric axis)
Conductor wall

Notes

  • The Number of Meshes 161
  • Analysis Time 0sec
  • Maximum Memory Usage 71MB

13

Corrugated Waveguide

Setup Condition and Analysis Type

Resonant analysis
Periodic Boundary Condition
Dispersion Curve

Notes

  • The Number of Meshes 1925
  • Analysis Time 1sec
  • Maximum Memory Usage 71MB

14

Coaxial Cable

Setup Condition and Analysis Type

Waveguide analysis
(Propagation constant analysis)
Integral path
Electric wall

Notes

  • The Number of Meshes 208
  • Analysis Time 3sec
  • Maximum Memory Usage 73MB

17

Microstrip Line Filter(Half Model)

Setup Condition and Analysis Type

Harmonic analysis
Half model
Microstrip line

Notes

  • The Number of Meshes 1130
  • Analysis Time 10sec
  • Maximum Memory Usage 101MB

18

Multilayer Capacitor

Setup Condition and Analysis Type

Harmonic analysis

Notes

  • The Number of Meshes 7370
  • Analysis Time 3min 10sec
  • Maximum Memory Usage 346MB

19

Balanced Line(Coupled Line) without Connector

Setup Condition and Analysis Type

Harmonic analysis
Differential mode

Notes

  • The Number of Meshes 6368
  • Analysis Time 34sec
  • Maximum Memory Usage 215MB

20

Balanced Line(Coupled Line) without Connector

Setup Condition and Analysis Type

Harmonic analysis
Differential mode

Notes

  • The Number of Meshes 10115
  • Analysis Time 1min 8sec
  • Maximum Memory Usage 292MB

21

Waveguide Analysis of Balanced Line

Setup Condition and Analysis Type

Waveguide analysis
Differential mode, Common mode

Notes

  • The Number of Meshes 364
  • Analysis Time 7sec
  • Maximum Memory Usage 79MB

22

S-Parameter Analysis of Balanced Line

Setup Condition and Analysis Type

Harmonic analysis
Differential mode, Common mode

Notes

  • The Number of Meshes 19792
  • Analysis Time 1min 54sec
  • Maximum Memory Usage 970MB

23

Mixed-Mode S-Parameters Analysis of Balanced Line

Setup Condition and Analysis Type

Harmonic analysis
Propagation mode transformation
Differential mode, Common mode

Notes

  • The Number of Meshes 23561
  • Analysis Time 2min 35sec
  • Maximum Memory Usage 1133MB

24

Waveguide-to-Coaxial Adapter

Setup Condition and Analysis Type

Harmonic analysis

Notes

  • The Number of Meshes 5217
  • Analysis Time 25sec
  • Maximum Memory Usage 204MB

25

Antenna

Setup Condition and Analysis Type

Harmonic analysis
Lumped constant

Notes

  • The Number of Meshes 11866
  • Analysis Time 3min 5sec
  • Maximum Memory Usage 580MB

26

Patch Antenna Array

Setup Condition and Analysis Type

Harmonic analysis
Field Superposition Setting

Notes

  • The Number of Meshes 12816
  • Analysis Time 1min 5sec
  • Maximum Memory Usage 590MB

27

TDR Analysis

Setup Condition and Analysis Type

Harmonic analysis

Notes

  • The Number of Meshes 36786
  • Analysis Time 2min 37sec
  • Maximum Memory Usage 766MB

28

Coil-to-Coil Power Transfer

Setup Condition and Analysis Type

Harmonic analysis

Notes

  • The Number of Meshes 22613
  • Analysis Time 1min 55sec
  • Maximum Memory Usage 905MB

29

Plane Waves

Setup Condition and Analysis Type

Harmonic analysis
Incident wave (plane wave)

Notes

  • The Number of Meshes 6812
  • Analysis Time 5sec
  • Maximum Memory Usage 403MB

30

Dipole and Monopole Antennas

Setup Condition and Analysis Type

Harmonic Analysis
Plane of Symmetry and Infinite Ground Plane

Notes

  • The Number of Meshes 14075
  • Analysis Time 50sec
  • Maximum Memory Usage 765MB

31

Murata’s RF Inductor

Setup Condition and Analysis Type

Harmonic analysis

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

32

Murata’s MAGICSTRAP®

Setup Condition and Analysis Type

Harmonic analysis

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

33

Propagation Mode in the Waveguide

Setup Condition and Analysis Type

Harmonic analysis
Number of precalculated modes
Number of modes used in the actual analysis
Select modes

Notes

  • The Number of Meshes Step 1:7634 Step 2:7414
  • Analysis Time Step 1:11sec Step 2:11sec
  • Maximum Memory Usage Step 1:182MB Step 2:273MB

34

Electrically Isolated Ground Electrode

Setup Condition and Analysis Type

Harmonic analysis
Propagation mode transformation
Ground

Notes

  • The Number of Meshes 37318
  • Analysis Time 1min 54sec
  • Maximum Memory Usage 1605MB

35

Minute Dipole Antenna

Setup Condition and Analysis Type

Current port

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

36

Diplexer

Setup Condition and Analysis Type

Harmonic analysis
Set frequency to apply adaptive meshing

Notes

  • The Number of Meshes 2607
  • Analysis Time
  • Maximum Memory Usage 124MB

37

Electromagnetic Field Correction

Setup Condition and Analysis Type

Harmonic Analysis
Correct errors of the electromagnetic field originated in the open boundary

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

38

TDR Analysis with Transient Analysis

Setup Condition and Analysis Type

Transient analysis
Input at each port
Impulse, Stepped wave

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

39

Charge and Discharge of Capacitor

Setup Condition and Analysis Type

Transient analysis
Voltage port
Lumped-constant boundary

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

40

Circular Patch Antenna

Setup Condition and Analysis Type

Transient analysis
Input at each port
Output field
Restart

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

41

Frequency-Selective Reflector

Setup Condition and Analysis Type

Harmonic analysis
Port larger than wavelength

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

42

Wireless Power Transfer Using Electromagnetic Resonance

Setup Condition and Analysis Type

Harmonic analysis
Open boundary

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

43

Ground-Penetrating Radar

Setup Condition and Analysis Type

Transient analysis
Input at each port
Output field

Notes

  • The Number of Meshes
  • Analysis Time
  • Maximum Memory Usage

Thermal Analysis・Electromagnetic Analysis・Piezoelectric Analysis

Thermal Analysis・Electromagnetic Analysis

Back to Product