Femtet2026.0 Help/Manual
 

Home / Examples / Fluid Analysis [Bernoulli] / Example 27: Slot-die coating analysis

 

Example 27: Slot-die coating analysis

General

  • Simulation of a film coating process using a slot die.
     

  • The coating liquid supplied from the top of the model is applied to a substrate moving at a constant velocity.

  • Compare the differences between cases with and without upstream reduced pressure.


  • Results will vary depending on Femtet version and the PC environment.

Analysis Model Download

  • Project file Download (Save the project file before open. Femtet 2026 or later is required.)

Analysis Space

Item

Subject

Analysis Space

2D

Model Unit

mm

 

Analysis Condition

 

Item

Tab

Settings

Solver

Solver Selection

Fluid Analysis [Bernoulli]

Analysis Type

Fluid Analysis

Transient analysis

Laminar Flow/Turbulent Flow

Fluid Analysis

Select [Laminar Flow]

Flow Type

Fluid Analysis

[Internal Flow] : Select

[Automatic Fluid Creation] : Deselect

Free Surface Analysis (VOF Method)

Fluid Analysis

Free Surface Analysis (VOF Method): Select

Free Surface Analysis (VOF Method) Setting

Fluid Analysis

Phase Setting: Register [000_Air] and Coating_Liquid.

 

Take into account weight: Select

Take into account surface tension: Select

Phase Pair Setting:

Phase 1

Phase 2

Surface Tension

Contact Angle

000_Air

Coating_Liquid

0.0611

45

Timestep [Automatic]

Transient Analysis

Item

Subject

Timestep

Automatic
Finish Time: : 0.1 [s]

Finish Time

0.1 [s]

Maximum Number of Calculation Steps

1000

Specify the output interval

Specify the output interval : Select

Detailed Automatic Timestep Setting

Adjust referring to Courant number : Select
Courant Number : 1

Mesh(Fluid) setting

Mesh Setting

General Mesh Size : 0.025 [mm]

Generate Layer Mesh : Deselect

Element Type : Rectangular-Free/Sweep Mesh

Fluid part Control Volume Type: Cell-centered Base

 

 

 

Graphical Objects

The initial state of the coating liquid is set using a rectangle body. The portion overlapping the rectangle body defines the initial shape of the coating liquid.

The coating liquid is supplied from the top. Set the coating liquid as the Inflow condition and specify its flow velocity.

The bottom surface is set as a moving wall to convey the coating liquid to the right-hand outlet.

For the left opening, specify natural inflow/outflow in the model and a negative pressure in the model_reduced pressure.

 

 

 

Body Attribute and Material Setting

Body Number/Type

Body Attribute Name

Material Name

5/Face

Slot_Die

000_Air *

6/Face

Initial

Coating_Liquid

* Available from the material DB

 

The material properties Coating_Liquid are set as follows.

Material name

Tab

Properties

Coating_Liquid

Density

1200 [kg/m3]

Viscosity

0.025 [Pa*s]

Boundary Conditions

Boundary Condition Name/Topology

Tab

Boundary Condition Type

Subject

Inlet/Edge

Fluid

Inflow

Select [Forced Inflow].

Flow Velocity: 0.17 [m/s]

Free Surface Analysis (VOF Method) Setting :

Inflow Phase : Coating_Liquid

Outlet/Edge

Fluid

Inflow/Outflow

Natural Inflow/Outflow

Pressure_Inlet/Face

Fluid

Inflow/Outflow

No reduced pressure : Natural Inflow/Outflow

Reduced pressure : Specify pressure : -2 [kPa]

Moving_Wal/Facel

Fluid

Solid Wall

Moving Wall : Select

Moving Wall Setting

Wall Motion : Translation

Velocity : 0.5[m/s]

 

Results

The volume fraction contours of phase 2 are shown below.

In the Reduced pressure model, bubbles enter and move toward the outlet.

 

Time

No Reduced pressure

Reduced pressure

0 [s]

0.01 [s]

0.015 [s]

0.0175 [s]

0.02 [s]

 

 

The liquid levels at the outlet are acquired by [VOF CaptureBoundary Macro.xlsm] and shown in the graph below.

 

In the No Reduced pressure Model the liquid surface shows large oscillations, whereas in the Reduced pressure Model it remains around 0.08 mm. This indicates that a uniform film can be formed.