Home / Examples / Coupled Analysis / Magnetic-Thermal-Fluid Analysis [Gauss/ Bernoulli/Watt] / Example 1: IH Cooking Heater (Magnetic-Thermal-Fluid Analysis)
Example 1: IH Cooking Heater (Magnetic-Thermal-Fluid Analysis)

General
-
This is an example of applying Fluid analysis additionally to the magnetic-thermal coupled analysis.
-
The model is a coil on the frying pan. AC current is applied to the coil to induce a current, resulting in a joule loss.
The heating caused by the joule loss is solved in the Thermal-Fluid analysis.
Surrounding air temperature and airflow patterns that cannot be obtained through heat conduction analysis can be visualized.
-
The vectors of the magnetic field and the temperature and flow velocities distribution by the heating are viewed.
-
Unless specified in the list below, the default conditions are applied.
-
Results will vary depending on Femtet version and the PC environment.
Analysis Model Download
-
Project file Download (Save the project file before open. Femtet 2026 or later is required.)
Analysis Space
|
Item |
Subject |
|
Analysis Space |
3D |
|
Model Unit |
mm |
Analysis Condition
|
Item |
Tab |
Settings |
|
Solver |
Solver Selection |
Magnetic Analysis [Gauss] Fluid Analysis [Bernoulli] Thermal Analysis [Watt]
Select [Buoyancy] and [Temperature] |
|
Magnetic-Analysis Type |
Magnetic/Thermal Analysis |
Harmonic analysis |
|
Fluid-Thermal Analysis Tab/Analysis Type |
Thermal-Fluid Analysis |
Steady-state analysis |
|
Options |
Thermal-Fluid Analysis |
Flow Type |
The frequency of the AC current is set to 10 [kHz].
|
Tab |
Item |
Subject |
|
Harmonic analysis |
Frequency Sweep Type |
Single frequency |
|
Frequency |
10 [kHz] |
Set the Mesh Tab as follows.
|
Tab |
Item |
Subject |
|
Mesh(Magnetic) |
Meshing Setup |
Set the general mesh size automatically: Deselect General Mesh Size: 20 [mm] |
|
Frequency-Dependent Meshing |
Reference Frequency: 10 [kHz] Surface Treatment for Conductors: |
|
|
Mesh(ThermalFluid) |
Meshing Setup |
Set the general mesh size automatically: Deselect General mesh size: 10 [mm] |
Model
Solid bodies of a frying pan (Metal) and a coil (Coil) are defined.
The air domain is automatically created in Magnetic analysis.
The air domain is also automatically created in Thermal-Fluid analysis.

Body Attribute and Material Setting
|
Body Number/Type |
Body Attribute Name |
Material Name |
|
1/Solid |
Coil1 |
008_Cu * |
|
3/Solid |
Coil2 |
008_Cu * |
|
11/Solid |
METAL |
METAL |
|
10/Solid |
Handle |
Wood |
* Available from the material DB
The material properties are set up as follows:
|
Material Name |
Tab |
Properties |
|
Wood |
Thermal Conductivity |
Thermal Conductivity: 0.5 [W/m/deg] |
|
METAL |
Permeability |
Relative Permeability: 5x103 |
|
Conductivity |
Conductivity Type: Conductor Conductivity: 1x107 |
|
|
Thermal Conductivity |
Thermal Conductivity: 80 |
Body attribute is set up as follows to apply current to the loop coil.
|
Body Attribute Name |
Tab |
Setting |
|
Coil |
Current |
Waveform: AC Current: 10 [A] Turns: 20 [Turns] Induced Current: None Direction: Loop Coil/Magnetic Field Direction Direction Vector of Magnetic Field: X=0, Y=0, Z=1 |
Results
The vectors of the current density calculated with loop coil are shown below.

The eddy current is induced in the pan.
The temperature contour as a result of Watt is shown below.

The temperature in the pan goes up to around 90[deg].
The vectors of flow velocities are shown as a result of Fluid analysis.
The cross section at X=0 is displayed.

A vortex appears on the pan surface and the resulting upward airflow can be visualized.