Femtet2026.0 Help/Manual
 

Home / Examples / Coupled Analysis / Magnetic-Thermal-Fluid Analysis [Gauss/ Bernoulli/Watt] / Example 1: IH Cooking Heater (Magnetic-Thermal-Fluid Analysis)

Example 1: IH Cooking Heater (Magnetic-Thermal-Fluid Analysis)


General

  • This is an example of applying Fluid analysis additionally to the magnetic-thermal coupled analysis.
     

  • The model is a coil on the frying pan. AC current is applied to the coil to induce a current, resulting in a joule loss.
    The heating caused by the joule loss is solved in the Thermal-Fluid analysis.
    Surrounding air temperature and airflow patterns that cannot be obtained through heat conduction analysis can be visualized.
     

  • The vectors of the magnetic field and the temperature and flow velocities distribution by the heating are viewed.
     

  • Unless specified in the list below, the default conditions are applied.
     

  • Results will vary depending on Femtet version and the PC environment.

Analysis Model Download

  • Project file Download (Save the project file before open. Femtet 2026 or later is required.)

 

Analysis Space

Item

Subject

Analysis Space

3D

Model Unit

mm

 

Analysis Condition

Item

Tab

Settings

Solver

Solver Selection

Magnetic Analysis [Gauss]

Fluid Analysis [Bernoulli]

Thermal Analysis [Watt]

 

Select [Buoyancy] and [Temperature]

Magnetic-Analysis Type

Magnetic/Thermal Analysis

Harmonic analysis

Fluid-Thermal Analysis Tab/Analysis Type

Thermal-Fluid Analysis

Steady-state analysis

Options

Thermal-Fluid Analysis

Flow Type
Select [External Flow].
Select [Automatic Fluid Creation]

 

The frequency of the AC current is set to 10 [kHz].

Tab

Item

Subject

Harmonic analysis

Frequency Sweep Type

Single frequency

Frequency

10 [kHz]

 

Set the Mesh Tab as follows.

Tab

Item

Subject

Mesh(Magnetic)

Meshing Setup

Set the general mesh size automatically: Deselect

General Mesh Size: 20 [mm]

Frequency-Dependent Meshing

Reference Frequency: 10 [kHz]

Surface Treatment for Conductors:
Generate skin meshes

Mesh(ThermalFluid)

Meshing Setup

Set the general mesh size automatically: Deselect

General mesh size: 10 [mm]

Model

Solid bodies of a frying pan (Metal) and a coil (Coil) are defined.

The air domain is automatically created in Magnetic analysis.

The air domain is also automatically created in Thermal-Fluid analysis.

 

Body Attribute and Material Setting

Body Number/Type

Body Attribute Name

Material Name

1/Solid

Coil1

008_Cu *

3/Solid

Coil2

008_Cu *

11/Solid

METAL

METAL

10/Solid

Handle

Wood

* Available from the material DB

 

The material properties are set up as follows:

Material Name

Tab

Properties

Wood

Thermal Conductivity

Thermal Conductivity: 0.5 [W/m/deg]

METAL

Permeability

Relative Permeability: 5x103

Conductivity

Conductivity Type: Conductor

Conductivity: 1x107

Thermal Conductivity

Thermal Conductivity: 80

 

Body attribute is set up as follows to apply current to the loop coil.

Body Attribute Name

Tab

Setting

Coil

Current

Waveform: AC

Current: 10 [A]

Turns: 20 [Turns]

Induced Current: None

Direction: Loop Coil/Magnetic Field Direction

Direction Vector of Magnetic Field: X=0, Y=0, Z=1

Results

The vectors of the current density calculated with loop coil are shown below.

 

 

The eddy current is induced in the pan.

 

The temperature contour as a result of Watt is shown below.

The temperature in the pan goes up to around 90[deg].

 

The vectors of flow velocities are shown as a result of Fluid analysis.

The cross section at X=0 is displayed.

 