Femtet2026.0 Help/Manual
 

Home / Examples / Electromagnetic Analysis [Hertz] / Example 26: Patch Antenna Array

Example 26: Patch Antenna Array


General

  • The characteristics of a patch antenna array are analyzed.
     

  • The directivity and S-parameters are solved.
     

  • Unless specified in the list below, the default conditions will be applied.
     

  • Results will vary depending on Femtet version and the PC environment.

Analysis Model Download

  • Project file Download (Save the project file before open. Femtet 2026 or later is required.)

 

Analysis Space

Item

Settings

Analysis Space

3D

Model Unit

mm

 

Analysis Conditions

Item

Settings

Solver

Electromagnetic Analysis [Hertz]

Analysis Type

Harmonic Analysis

 

 

Mesh tab, Harmonic analysis tab and Open boundary tab are set as follows.

Tab

Setting Item

Settings

Mesh Tab

Frequency-Dependent Meshing

Reference Frequency: 6x109 [Hz]

Select [The conductor bodies thicker than the skin depth constitute the boundary condition].

Harmonic analysis

Sweep Type

Select [Linear Step by Number of Divisions]

Sweep Setting

Minimum: 5×109 [Hz]

Maximum: 7x109 [Hz]

Number of Divisions: 100

Sweep Setting

Select Fast sweep

S-parameter Tolerance: 1x10-3

Input

1.0 [W]

Open boundary

Type

Absorbing Boundary

Order of Absorbing Boundary

1st-order

 

Model

Antenna pattern METAL is a sheet body created on a rectangle substrate SUBSTRATE.

It is covered with spherical air (AIR). Open boundary is set on the surface of AIR.

 

Body Attributes and Materials

Body Number/Type

Body Attribute Name

Material Name

1/Sheet

METAL

003_Ag

5/Sheet

METAL

003_Ag

10/Sheet

METAL

003_Ag

15/Solid

SUBSTRATE

006_Glass_epoxy

16/Sheet

METAL

003_Ag

19/Sheet

Imprinting body

 

20/Sheet

Imprinting body

 

24/Solid

AIR

000_Air

* Available from the material DB

 

Boundary Conditions

Boundary Condition Name/Topology

Tab

Boundary Condition Type

Settings

Port_001/Face

Electric

Port

Reference Impedance: Select [Specify]

and enter 50 [Ohm].

Number of Modes

Number of Precalculated Modes: 5

Number of Modes Used in the Actual 3D Analysis: 1

Select Modes: None

Port_002/Face

Electric

Port

Same as Above.

Outer Boundary Condition

Electric

Open Boundary

 

 

Results

S-parameter S11 is shown below.

 

 

The figure below shows the radiation pattern with the weighed input.

See the Field Superposition Setting for the detail.

 

 

 

MAG

PHASE [deg]

Red line

Port_001

1.0

0.0

Port_002

1.0

0.0

Black line

Port_001

1.0

0.0

Port_002

1.0

180