Home / Technical Notes / Thermal Analysis / Thermal Network Model
Thermal Network Model
1. Thermal Network Model (DELPHI compact model)
Overview
The DELPHI compact model [*1] is a form of Compact Thermal Model (CTM) that replaces a complex 3D heat-conduction detailed model (Detailed Model) for example of a semiconductor package with a small-node thermal resistance network (a thermal circuit).
Compared with detailed 3D models (FEM/CFD), it is computationally lightweight and is used to make components easier to handle in system-level thermal analyses (including enclosures, PCBs, and heat-dissipating parts).
[Thermal Network Model] feature provides the capability to incorporate such DELPHI compact thermal model (thermal resistance networks) into an analysis model and connect them to the surrounding thermal environment (board, enclosure, air, heatsink, etc.) to evaluate temperatures and heat flows.

Figure 1. Thermal Network Model
Configuration
Each node has a single temperature. The nodes consist of external nodes, which correspond to the package surfaces, and internal nodes, which are placed inside the package.
External nodes has a one-to-one correspondence with a region on the actual package surface and represents the area-averaged temperature of that region.
Internal nodes represent heat generation and heat capacity within the actual package as nodes.
The nodes are connected by thermal resistances, allowing the entire structure to be represented as a one-dimensional Thermal Network. See Figure 2. for details.

Figure 2. Node and thermal resistance
2. Handling in Femtet
DELPHI (steady-state) and D2ELPHI (transient) are not distinguished and are both treated as Thermal Network Models.
No limit exists on the number of thermal resistances that can be specified, even a two-resistance model [*2] consisting of only two thermal resistances, can be configured as a Thermal Network Model.
Please refer to [Body Attribute] > Thermal Network Model Tab for the details.
Internal node
Steady state analysis : A heat generating node can be defined as an internal node (equivalent to a junction).
Transient analysis : To reproduce transient responses, in addition to the heat generating node, heat capacity nodes may be defined as internal nodes.
[Body Attribute] > [Thermal Network Model Tab] > [Internal Node Settings] is for the setting of node name, heat generation and heat capacity value.

Figure 3. Internal Node Settings GUI
External node
External nodes are defined from the boundary conditions.
Apply the [Measurement Terminal - Thermal Circuit External Node] boundary condition to the surface intended as an external node to set it as an external node in the thermal circuit network model.
If a thermal boundary condition is to be applied to an external node, set the desired thermal boundary condition rather than the [Measurement Terminal / Thermal Circuit External Node] boundary condition.
[Examples of heat exchange between the Thermal Network Model and the surroundings]
1 Contact with the FEM domain
Set the [Measurement Terminal -Thermal Circuit External Node] boundary condition to the surface to be designated as the External node.
When the External node surface contacts the FEM domain, the entire interface between the External node and the FEM domain is computed to be approximately isothermal.
2 Heat transfer/Convection to the surroundings
Set the [Heat Transfer/Convection] boundary condition to the surface to be designated as the External node.
Heat is transferred from the External node surface to the surroundings using the specified heat transfer coefficient or convective conditions.
3 Fixed Temperature
Set the [Temperature] boundary condition to the surface to be designated as the External node.
The temperature of the External node can be specified.
Thermal Resistance
Thermal resistance can be set from [Body attribute] > [Thermal Network Model Tab] > [Resistance value settings] . Registered internal and external node names can be selected from the list.
When the node pair connected by a thermal resistance and the resistance value are entered, pushing [Add] send the entry to the Table.
The thermal resistances specified in this table are applied in the analysis.

Figure 4. Thermal Resistance Settings GUI
3. Analysis Flow
How to create and analyze DELPHI_Model from DetailedModel in this example
Procedures for creating and analyzing DELPHI_Model from DetailedModel in this example.
The MakeDELPHI macro below creates only steady state DELPHI models and does not support D2ELPHI (transient) models that include thermal capacitances.
(1) Download the Femtet Macro from Appication 41 [Deriving a DELPHI Model (1D Thermal Analysis Model) Using the Femtet Macro] (https://www.muratasoftware.com/en/case/watt09/)
(2) Refer to MakeDELPHIQuick_Manual_EN.pptx in the Downloads folder and run the MakeDELPHI macro. Creating DELPHI_Model from DetailedModel

Figure 5. Results of the MakeDELPHI macro (DELPHI model: Thermal Resistance tab)
(3) Refer to 2. [Handling in Femtet] and apply the obtained results in Femtet. MakeDELPHI results can be imported into the thermal resistance settings. Please refer to Thermal Network Model Tab for the details.
(4) Calculation results can be viewed in [Results Table] > [Thermal Network Model Information].
The first column of the table displays Body attribute name Node name. For each node have the temperature data , and heat generation in case of internal nodes or the heat flow passing through in case of .external nodes.
Heat flow is shown as a negative value when heat is released from an internal node to the surroundings, and as a positive value when heat is absorbed into the internal node.

Figure 6. Thermal Network Model Information and Table result
How to manually set up Thermal Network Model
If thermal-network data already exists, follow the steps below to manually set internal nodes, external nodes, and thermal resistances.
(1) Open the body attribute of the body to be treated as a thermal-network model. On the [Thermal Network Model] Tab, enable [Calculate as a Thermal Network body].
(2) If boundary conditions for external nodes have not been set yet, close the body attribute dialog.
(3) Assign boundary conditions to the faces intended as external nodes.
To treat a face as an external node that does not exchange heat with the surroundings, assign the "Measurement terminal / thermal-network external node" boundary condition.
To apply a thermal boundary condition to an external node, assign conditions such as [Heat transfer/Convection] or [Temperature] as appropriate.
(4) Reopen [Body Attribute] > [Thermal Network Model Tab] > [Internal Node Settings], specify internal node names, heat generation values, and thermal capacitances.
(5) In the Thermal Resistance settings, specify node-pair connections and corresponding thermal resistance values.
Internal nodes are selectable from the names registered in Internal Node Settings; external nodes are selectable from the names assigned via boundary conditions.
(6) Compute analysis and calculation results can be viewed in [Results Table] > [Thermal Network Model Information].
How to reuse Thermal Network Model
How to copy a thermal circuit network model within the same project.
(1) Select the body attribute with the Thermal Network Model information and execute [Copy] from the right click menu.
(2) After making copy, the two Thermal Network Model bodies share the same body attribute, so rename the body attribute of one of them.
To copy a body attribute name, select the name in Body Attribute Data
and use the right-click menu to [Copy], [Paste], and Rename.
(3) Assign the newly created body attribute data to the copied Thermal Network Model body.
Next, how to reuse a Thermal Model (with internal nodes, external nodes, and thermal resistance values already set) in another project file.
(1) In [File] > [General Settings] > [Database] tab, confirm if the Body Attribute Data folder is available in the Folder Name to save User DB setting. If not, please enter the folder name to save. See [How to Use the Model DB] for the detail.
(2) Select the body attribute name with the Thermal Network Model settings and execute [Transfer Attributes to User DB] from the right click menu. See [Project Tree] >[Database] for the detail.
(3) In the model window, select all bodies of the Thermal Network Model to be added to the model database, then choose [Register in Model DB]
from the [Model] tab.
See [Model DB Tree], [How to Use the Model DB] for the details.
(4) Open the project where the Thermal Network Model will be used and import the model data. See procedure [How to Use Model DB] > [How to import model data].
References:
[1] JEDEC STANDARD, JESD15-4, DELPHI Compact Thermal Model Guideline
[2] JEDEC STANDARD, JESD15-3, Two-Resistor Compact Thermal Model Guideline