Femtet2026.0 Help/Manual
 

Home / Examples / Thermal Analysis [Watt] / Example 3: Block Containing Heating Element (Steady-State Analysis)

Example 3: Block Containing Heating Element (Steady-State Analysis)


General

  • A heating element is placed in the center of the block. The ambient temperature is constant.
     

  • The temperature distribution and the heat flux vectors are solved.
     

  • Unless specified in the list below, the default conditions will be applied.
     

  • Results will vary depending on Femtet version and the PC environment.

Analysis Model Download

  • Project file Download (Save the project file before open. Femtet 2026 or later is required.)

 

Analysis Space

Item

Settings

Analysis Space

3D

Model Unit

mm

 

Analysis Conditions

Item

Settings

Solver

Thermal Analysis [Watt]

Analysis Type

Steady-state Analysis

Options

N/A

Model

A cylindrical heat source (Nichrome) is placed in the center of a glass-epoxy block.

The heat quantity is set in the body attribute. The ambient temperature is set to 0[deg] in the external boundary condition.

Body Attributes and Materials

Body Number/Type

Body Attribute Name

Material Name

Mesh Size

0/Solid

VOL1

006_Glass_epoxy *

 

1/Solid

VOL2

109_Nichrome *

2

* Available from the material DB

 

The heat quantity of VOL2 is set up as follows.

Body Attribute Name

Tab

Settings

VOL2

Heat Quantity

10 [W]

Boundary Conditions

Boundary Condition Name/Topology

Tab

Boundary Condition Type

Settings

Outer Boundary Condition

Heat

Temperature

0 [deg]

 

To set Outer Boundary Condition, go to the [Model] tab
 


 

and click [Outer Boundary Condition] .

Results

A cross section's temperature distribution is shown below.

The hottest point is the center of the heat source. The temperature is 266 [deg].

 

Shown below is the isosurface contour of the temperature distribution. [Shading] and [Translucency] are enabled.

The 3D temperature gradient is exhibited clearly around the heat source.