Example 32: Control transient heat generation within a specified temperature range


General

  • Two heat sources are placed on a substrate.
    The heat is released from the whole of the substrate to the ambient by natural convection. The transient analysis is performed.

  • The main chip (heat source) is controlled to keep the sub chip within a specified temperature range. (thermostat control)
     

  • Use the same models of Example 19: Time-Dependent Heat Source (Transient Analysis).
     

  • The temperature distribution and the heat flux vectors are solved.
     

  • Unless specified in the list below, the default conditions are applied.
     

  • Results will vary depending on Femtet version and the PC environment.

Analysis Model Download

  • Project file Download (Save the project file before open. Femtet 2026 or later is required.)

 

Analysis Space

Item

Subject

Analysis Space

3D

Model Unit

mm

 

Analysis Condition

Item

Subject

Solver

Thermal Analysis [Watt]

Analysis Type

Transient Analysis

Options

None

Mesh size

5[mm]

 

The transient analysis is set up in transient tab as follows. As the calculation steps is 20 and the timestep is 60 sec.

Therefore, the temperature distributions for 1200 sec

are solved.

Tab

Item

Subject

Transient analysis

Table

Number

Number of Calculation Steps

Output interval

Timestep [s]

1

20

1

60

 

Initial Temperature

25 [deg]

Monitoring

Temperature

Adding Body Attribute/SUBCHIP/Maximum Value

Graphical Objects

The model is the same as examples 7 and 14. The material properties and the boundary conditions are the same as well.

Graphical Objects

  • To use the boundary condition of [Natural Convection (Automatic Coefficient Calculation)], the model must be oriented so that the negative Z direction points to the ground.

 

Body Attributes and Materials

The finer mesh size is set for via holes (HOLE), where the heat flux is expected to change drastically.


Body Number/Type

Body Attribute Name

Material Name

Mesh Size

0/Solid

SUB

006_Glass_epoxy *1

 

1/Solid

GND

008_Cu *1

 

2/Solid

MAINCHIP

001_Alumina *2

 

3/Solid

SUBCHIP

001_Alumina *2

 

4/Solid

HOLE

008_Cu *1

0.5

5/Solid

HOLE

008_Cu *1

0.5

6/Solid

HOLE

008_Cu *1

0.5

7/Solid

HOLE

008_Cu *1

0.5

8/Solid

HOLE

008_Cu *1

0.5

9/Solid

HOLE

008_Cu *1

0.5

10/Solid

HOLE

008_Cu *1

0.5

11/Solid

HOLE

008_Cu *1

0.5

*1 Available from the material DB.

*2 Available from the material DB. The specific heat is manually entered.

 

The heat quantities of MAINCHIP and SUBCHIP are set up as follows.
Apply [Temperature Control Settings] to the MAINCHIP heat generation. Use the monitoring information added under [Analysis Conditions] > [Monitoring] tab to specify the temperature to monitor.

Also specify the temperature range at that monitoring point based on the control temperature.

The following settings enable a thermostat control that switches MAINCHIP heat generation ON/OFF to keep the SUBCHIP maximum temperature within 31-32 deg C.

 

Body attribute name

Tab

Setting

MAINCHIP

Heat Quantity

0.2 [W]


Temperature Control Settings

Select Control by monitoring temperature

Target monitoring Temperature : Body Attribute/SUBCHIP/Maximum Value

Control temperature : Upper Limit 32 deg C Lower Limit 31 deg C

SUBCHIP

Heat Quantity

0 [W]

Boundary Conditions

Select [Natural Convection (Automatic Coefficient Calculation)] on the outer boundary condition.

 

Boundary Condition Name/Topology

Tab

Boundary Condition Type

Subject

Outer Boundary Condition

Thermal

Heat transfer/Convection

Natural Convection (Automatic Coefficient Calculation)

Room Temperature: 25 [deg]

 

* The correction coefficient for the natural convection is calculated automatically. For the details, please refer to the Thermal tab.

 

Results

A plot of the SUBCHIP maximum temperature versus time is shown.

 

The plot indicates the temperature is controlled around 31-32 deg C.

When the upper limit (32 deg C) is exceeded, MAINCHIP heat generation switches off (0 W), causing the SUBCHIP temperature to fall. When the lower limit (31 deg C) is undershot, MAINCHIP heat generation switches on (0.2 W), causing the SUBCHIP temperature to rise.

The delayed SUBCHIP temperature response after switching at the lower limit is attributed to the distance between MAINCHIP and SUBCHIP, so the heating effect is not transmitted immediately.

 

Temperatures and heat densities at the switching events at 540 s and 600 s are shown.

Temperature distribution in 540 sec

Temperature distribution in 600 sec

 

Heat Density in 540 sec

Heat Density in 600 sec

 

The maximum temperature decreases after heat generation is switched OFF, indicating the effect of turning the heater off.

The Heat Density also reflects the ON/OFF switching.