Home / Executing Simulation / Piezoelectric Dispersion Curve Analysis
Piezoelectric Dispersion Curve Analysis
Compute Piezoelectric Dispersion Curve Analysis
See Example 39: Dispersion Curve (Piezoelectric) for the reference.
Algorithm
A graph with wavenumber on the horizontal axis and frequency on the vertical axis is used, and the dispersion curve is obtained by connecting the maximum values of the admittance.
The admittance frequency response can be obtained by piezoelectric harmonic analysis. Since a direct sweep of the wavenumber is not possible, analyses are performed by inputting the phase difference of the periodic boundary corresponding to each wavenumber. Use parametric analysis to sweep the wavenumber (input actually as phase difference [deg]), perform harmonic analysis to sweep frequency, obtain the admittance, and plot the graph.
Piezoelectric Dispersion Curve Preparation
A model capable of calculating admittance is required, so boundary conditions that apply a voltage are necessary.
Furthermore, periodic boundary conditions are required to perform a wavenumber sweep. Femtet does not accept wavenumber input directly. Sweep the variables kre and kim that correspond to the wavenumber, compute the phase difference from them, and use that in the analysis. The variable names [kre] and [kim] are required. [kre] corresponds to the real part of the wavenumber and [kim] corresponds to the imaginary part.
The formula that converts the wavenumber to a phase difference must be entered into the periodic boundary condition dialog. See Example 39: Dispersion Curve (Piezoelectric) for the reference.
Execute
In the [Mode]l tab > [Run Mesher/Solver] Sub menu > [Piezoelectric Dispersion Curve Analysis] to open the Piezoelectric Dispersion Curve Analysis dialog shown in Figure 1. Pressing the [Run solver] button starts the analysis. A frequency sweep and a parametric sweep are performed, so the analysis takes time.
[The time required for the dispersion curve analysis] = [The time for the harmonic analysis frequency sweep] x [The number of specified wavenumber steps]
Result
Clicking the [Graph] button in the Piezoelectric Dispersion Curve Analysis displays the graph shown in Figure 2
The positive side of the horizontal axis corresponds to the real part of the wavenumber, and the negative side corresponds to the imaginary part.
The inputs Minimum and Maximum at the bottom of the graph are used to change the color scale range.
The graph plots log IYI as shown in the title. Higher values are displayed in red, so the red line corresponds to the dispersion curve. The blue line corresponds to the curve connecting the antiresonances.
The graph is based on admittance frequency response data in s1p file. The results folder contains s1p files corresponding to each calculated wavenumber.

Figure 1. Piezoelectric Dispersion Curve Analysis Dialog

Figure 2. Piezoelectric Dispersion Curve
-
The positive region of the wavenumber corresponds to the real part, and the negative region corresponds to the imaginary part.


