Home / How to Set Analysis Condition / Fluid Analysis [Bernoulli] / Analysis Considering Rotation (MRF)
Analysis Considering Rotation (MRF)
|
Setting Items |
Notes |
|
Rotating region setting method |
Select either the solid region the fluid region settings. Set as Solid region (automatic creation) : When a body attribute corresponding to the impeller is selected, a fluid body for the rotating region is automatically created around the specified body attribute. Set as Fluid region (manual creation) : Select the body attribute corresponding to the pre-created rotating region. |
|
Rotation parameter setting |
Enter parameters on the left side of the GUI and add entries to the list on the right side to define the rotating region.
Rotating region setting Select the body attribute according to the method specified in [Rotating region setting method]. [Set as Solid region] displays attributes for solid bodies, and [Set as Fluid region] displays attributes for fluid bodies. Attributes can be selected.
Set as Solid region : Selecting the body attribute corresponding to the impeller automatically creates a rotating region sized as specified in Detailed Settings (body attribute name: impeller attribute name + _MRFAuto). The rotating region is created during mesh generation. When the impeller body attribute is selected, the rotation center and axis are automatically obtained. If the number of impeller blades set in the solid region is two or less, an inappropriate rotation axis vector may be obtained. In [Region creation Settings], specify the size ratio of the rotating region relative to the impeller size. Impeller height and diameter are obtained automatically, and the rotating region is created at the specified size ratio as a cylinder in 3D and as a circle in 2D. See [Section 2.1 Rotation Region] on technical note Analysis Considering Rotation (MRF) about the size setting. If the specified size would interfere with surrounding components, a rotating region reduced in size is created automatically. See [Section 2.5 Mesh size] on technical note Analysis Considering Rotation (MRF) about mesh size for rotational region
[Set as Fluid region] assigns fluid body properties for cylindrical or annular geometries For non-cylindrical or non-annular shapes, determination of the rotation axis and center may fail, and the geometry will be marked as invalid. See [Section 2.1 Rotation Region] on technical note Analysis Considering Rotation (MRF) about other conditions that must be satisfied for a rotational region.
Rotation center / Rotation axis Enter the rotation center (a point on the rotation axis) and the rotation axis (direction). Selecting a body attribute in [Rotating region setting] automatically retrieves the rotation center and axis. If automatic retrieval fails or retrieved values are inappropriate, manual entry is permitted. The rotation axis is normalized internally. No prior normalization is required.
Angular Velocity Enter the angular velocity for fluid rotation. For transient analysis, a time-dependent rotation-speed table can be entered. Negative values indicate rotation in the opposite direction. Rotation direction can be verified by the arrow displayed on the model after registration in the list.
Reference Basis When a rotating region rotates relative to another (for example, spinning while orbiting), enable [Use another rotating region as the reference point].A previously added rotating region from the list can be selected as the reference.
Mesh Size of Rotational Region Displayed only when [Set as Solid Region] is selected, allows specification of the mesh size for the automatic created rotating region.If left blank, the mesh size is automatically determined from the mesh size assigned to the impeller body and the impeller geometry. When [Set as Fluid Region] is selected, specify the mesh size using the standard mesh size specification procedure. (See [How to Set Specific Mesh Size for a Part of Model])
|
|
Initialization settings |
Enabling [Initialize the rotating region with rotational flow] initializes rotational regions with a rotational flow corresponding to the specified rotational speed. Initialization may improve convergence. This option is automatically disabled for transient analyses. The setting is applied uniformly to all rotating regions. |


