Home / Technical Notes / Fluid Analysis/Thermal-Fluid Analysis / Analysis Considering Rotation (MRF)
Analysis Considering Rotation (MRF)
Description of the Analysis considering rotation (MRF: Multiple Reference Frame ) for the Fluid analysis.
Multiple Reference Frame (MRF) enables simultaneous treatment of a stationary region and a rotating region (RRF: Rotating Reference Frame), suitable for steady-flow analyses of impellers, fans, pumps, and similar rotating machinery.
1. MRF Method
1.1. Overview
Multiple Reference Frame (MRF) is a steady state method that solves part of the region in a rotating frame (relative frame) and the remainder in a stationary frame (absolute frame) simultaneously.
Interactions between rotor and stator are represented as Coriolis and centrifugal forces, without requiring relative mesh motion.
Applicable to pseudo steady flows rotating at a constant angular velocity.
1.2 Solved Equation
See [Differential Equations Solved in the Fluid Analysis/Thermal-Fluid Analysis] for more information.
1.3 Limit Determination of Application Range
Applicable cases for use
-Steady performance evaluation at a constant speed (fans, pumps, blowers, centrifuges, mixers - e.g., flow pressure characteristics and torque)
-When blade-passing unsteady effects can be averaged and a mean interaction is sufficient
-Multiple rotating shafts exist but the rotating regions are sufficiently separated so mutual interaction is weak
Not suitable / Cases requiring caution
-Rotating flows with strong unsteady behavior (blade passage, time-varying rotational speed, surging, stall)
-Situations where azimuthal phase information is important (azimuthal unsteady effects from blade passage)
-Strong interaction between multiple independent rotating shafts
-When flow inside the rotating region is asymmetric due to side inflow, buoyancy, etc.
Femtet supports analyses with time-varying rotational speed. However, only pseudo-steady solutions at each time instant are obtained.
Thus, unsteady effects caused by time variations are not captured.
When interaction between rotating regions is strong (e.g., strong unsteady blade-passing effects or dominant close-range interactions), MRF - being a steady approximation - can be inappropriate or lack accuracy.
A sliding mesh approach is commonly used to capture unsteady behavior. This capability is not available in Femtet.
Likewise, if flow inside the rotating region is asymmetric, MRF is unsuitable and sliding mesh analysis is required.
Considerations when using MRF
MRF is enabled by selecting [Analysis Considering Rotation (MRF)].
See [How to Set Analysis Condition] > [Fluid Analysis] > [Analysis Considering Rotation (MRF)] for the details.
2.1 Rotating Reference Frame (RRF)
Define a cylindrical or annular volume that fully encloses the rotating components (impeller, fan blades, etc.).
Keep the rotating region separated from surrounding stationary parts by several mesh cells.
Ensure the impeller tip lies entirely within the rotating region.
Do not include stationary walls or non-rotating, non-axisymmetric fixed shafts inside the rotating region.
Overlapping rotating regions are not allowed.
Choose the rotating region size so the quasi-steady assumption holds at its inner and outer boundaries. No strict guideline exists, generally avoid placing the boundary too close to the impeller or baffles. [1]
If the rotating region is too close to the impeller or baffles, unsteady effects not captured by MRF can become significant.
For systems that generate radial flow such as stirred tanks and centrifugal fans, recommend increasing the radial extent of the rotating region. For systems that generate axial flow such as axial-flow fans, increase the axial extent of the rotating region.
Several studies have investigated the effect of rotating region size [2][3], reporting that the required size depends on the computational model and the Reynolds number.
Rotating region size is often chosen based on impeller height or diameter.
In Femtet, selecting [Set as Solid Region] creates a rotating region automatically using the impeller size and a specified scale factor.
The default scale is 1.5 times the impeller height/diameter, as used in several publications. [2][3][4]
See [How to Set Analysis Condition] > [Fluid Analysis] > [Analysis Considering Rotation (MRF)] for the details.
2.2 Rotation Condition
Sets the Rotation Axis Vector (direction), coordinates of center and angular velocity.
2.3 Boundary Condition
Below is the notes about boundary conditions for the rotating region
No special boundary condition is required at the interface between rotating and stationary regions.
If no boundary condition is specified inside the rotating region, a no-slip condition is applied.
Velocity type boundary conditions inside the rotating region are interpreted as velocities relative to the rotation.
A solid wall set as a Static Wall inside the rotating region is treated as stationary relative to the rotation.
A solid wall set as a Moving Wall inside the rotating region specifies rotation in the absolute reference frame.
Therefore, to enforce absolute velocity = 0 inside the rotating region, set the corresponding Moving Wall rotation speed to 0.
2.4 Initial Condition
Providing a stationary field or a rigid body rotational flow as the initial velocity can help convergence.
Using a transient setup that ramps the rotational speed gradually may improve convergence.
See [How to Set Analysis Condition] > [Fluid Analysis] > [Analysis Considering Rotation (MRF)] for the details.
2.5 Mesh size
When the rotating region is automatic created by selecting [Set as Solid Region],
the mesh size is determined by the following rules.
- [How to Set Analysis Condition] > [Fluid Analysis] > [Analysis Considering Rotation (MRF)] for mesh setting..
If mesh size is not specified, Femtet automatically determines the rotating region mesh size
based on the impeller geometry and the impeller mesh settings.
When the rotating region is defined [Set as Fluid region],
set the mesh size so that multiple mesh elements span the distance from the impeller tip to the interface between the rotating and stationary regions as much as possible.
If the impeller body mesh is too coarse, the mesh at the impeller rotating region interface may also become coarse, which can lead to divergence.
Make the impeller body mesh size comparable to the rotating region mesh size.
2.6 When the computation diverges
For MRF analyses, Femtet's default relaxation factors can be too large and may degrade convergence; adjusting the relaxation factors can be effective.
See the technical note [Fluid] > If Fluid Analysis/Thermal-Fluid Analysis Does Not Converge for the details and other countermeasures.
Also, improvements may be achieved by the initial condition settings described in section 2.4.
References
[1] Mittal & Kikugawa, 2021. Computational fluid dynamics simulation of a stirred tank reactor. Mater. Today Proc., 46, 11015-11019.
[2] A. D. de la Concha-Goomez et al., 2019. Effect of the rotating reference frame size for simulating a mixing straight-blade impeller in a baffled stirred tank. Rev. Mex. Ing. Quim., 18(3), 1143-1160.
[3] Deglon & Meyer, 2006. CFD modelling of stirred tanks: Numerical considerations. Minerals Engineering, 19, 1059-1068.
[4] Ali et al., 2020. CFD simulation model for mixing tank using MRF impeller rotation. Int. J. Tech. Res. Sci. (ICACCG2020), p. 17.