Femtet2026.0 Help/Manual
 

Home / Examples / Fluid Analysis [Bernoulli] / Example 25: Multi-impeller spin/revolution flow

 

Example 25: Multi-impeller spin/revolution flow

General

  • Analyzes a state in which the entire model undergoes an overall rotational flow (revolution), and four impellers additionally rotate (spin).
     

  • This example use MRF rotating region automatic creation settings (Set as Solid region).

  • Use another rotating region as the reference point of each impeller's MRF rotating region

  • Results will vary depending on Femtet version and the PC environment.

Analysis Model Download

  • Project file Download (Save the project file before open. Femtet 2026 or later is required.)

Analysis Space

Item

Subject

Analysis Space

2D

Model Unit

mm

 

Analysis Condition

Item

Tab

Settings

Solver

Solver Selection

Fluid Analysis [Bernoulli]

Analysis Type

Fluid Analysis

Steady-state analysis

Flow Type

Fluid Analysis

Select [Internal Flow].

Analysis Considering Rotation (MRF)

Fluid Analysis

Select [Analysis Considering Rotation (MRF)]

Meshing Setup

Mesh(Fluid)

General Mesh Size: 0.5 [mm]

(Mesh size on the rotating region of model 2 is 0.25mm)

 

Element Type: Polygon Free [Fluid]

Control Volume Type: Cell-centered Base
Generate Layer Mesh: Deselect

 

Setting for Analysis Considering Rotation (MRF)

 

Rotating Region

Setting Method

Rotation Center Coordinates [m]

Rotation Axis Vector

Angular Velocity [deg/s]

Time Dependency

Reference Basis

all Fluid Domain (0, 0, 0) (0, 1, 0) -6 None Absolute
left Model 1: Solid region
Model 2: Fluid region
(-0.005, 0, 0) (0, 1, 0) 30 None all
btm Model 1: Solid region
Model 2: Fluid region
(0.0, -0.005) (0, 1, 0) 30 None all
right Model 1: Solid region
Model 2: Fluid region
(0,005.0, 0) (0, 1, 0) 30 None all
top Model 1: Solid region
Model 2: Fluid region
(0, 0, 0.005) (0, 1, 0) 30 None all

 

Graphical Objects

Create a circular fluid body representing the revolving (overall rotational) flow with a radius of 10 mm. Place the four impellers at coordinates (5, 0), (0, 5), (-5, 0), and (0, -5) mm.

The rotating region bodies around the impellers are automatically generated when [Set as Solid Region] is set for [Rotating Region Settings method] on [Analysis Condition]/[Fluid Analysis]/[Analysis Considering Rotation (MRF)]. (Model 1: Rotating region is set as Solid Region.)

Circular rotating- region bodies can also be created and set manually. (Model 2: Rotating region is set as Fluid Region.)

 

 

 

Body Attribute and Material Setting

Body Number/Type

Body Attribute Name

Material Name

0/Fluid

all

100_Water *

1/Solid

top

104_Stainless_steel *

2/Solid

right

104_Stainless_steel *

3/Solid

left

104_Stainless_steel *

4/Solid

btm

104_Stainless_steel *

(*) Available from the material DB.

Boundary Conditions

No modification from default setting.

Results

-Model 1: Rotating region is set as solid region (Automatic creation settings)

Specific mesh size is not defined for the Rotating regions and impeller bodies. Mesh sizes are automatically calculated for them.

When specifying the mesh size for the rotating region, mesh sizes must also be specified for the impeller bodies.

See [How to Set Analysis Condition][Fluid Analysis][Analysis Considering Rotation (MRF)]], [Technical Note][Analysis Considering Rotation (MRF)] for the details.

 

The vectors of the flow velocity distribution are shown below. Vector directions indicate the impeller's orbital angular velocity exceeds its spin angular velocity.

 

 

-Model 2: Rotating region is set as Fluid region (Manual settings)

Mesh size 0.25 is applied to each impeller rotating region (top, bottom, right, left) to refine the Rotating Region mesh.

To avoid numerical instability near the impeller, the impeller body is also assigned mesh size 0.25.

The manually created rotating regions in this model are smaller than the automatically generated ones.

 

The vectors of the flow velocity distribution are shown below. Due to differences in Rotating Region size and mesh size, the maximum value is slightly different from that of the Solid Region model.