Femtet2026.0 Help/Manual
 

Home / Examples / Fluid Analysis [Bernoulli] / Example 26: Flow analysis of a stirred tank (no baffles)

 

Example 26: Flow analysis of a stirred tank (no baffles)

General

  • Analysis of two impellers rotating inside a stirred tank.
     

  • This example use MRF rotating region automatic creation settings (Set as Solid region).

  •  
  • Results will vary depending on Femtet version and the PC environment.

Analysis Model Download

  • Project file Download (Save the project file before open. Femtet 2026 or later is required.)

  • 3D CAD model (only x_t data) Download (Save the file before open)

Analysis Space

Item

Subject

Analysis Space

3D

Model Unit

mm

 

Analysis Condition

Item

Tab

Settings

Solver

Solver Selection

Fluid Analysis [Bernoulli]

Analysis Type

Fluid Analysis

Steady-state analysis

Flow Type

Fluid Analysis

Select [Internal Flow].

Analysis Considering Rotation (MRF)

Fluid Analysis

Select [Analysis Considering Rotation (MRF)]

Meshing Setup

Mesh(Fluid)

General Mesh Size: 80 [mm]

 

Element Type: Polyhedron Free [Fluid]

Control Volume Type: Cell-centered Base

 

Setting for Analysis Considering Rotation (MRF)

 

The body attribute of each impeller must be specified.

Rotating Region

Setting Method

Rotation Center Coordinates [m]

Rotation Axis Vector

Angular Velocity [deg/s]

Time Dependency

Reference Basis

Impeller1 Solid Region Automatic Acquisition Automatic Acquisition 60 None Absolute
Impeller2 Solid Region Automatic Acquisition Automatic Acquisition 60 None Absolute

Automatic acquisition values are used for the Rotation center coordinates and Rotation axis vector. Selecting the body attribute in Rotating region automatically acquires the Rotation center coordinates and Rotation axis vector.

Note that the values may become inappropriate If the impeller has only two blades. See [How to Set Analysis Condition][Fluid Analysis][Analysis Considering Rotation (MRF)] for the details.

Graphical Objects

Consider a model of a shaft with two impellers inside a stirred tank. The stirred tank is simplified by the models with no baffles and three-bladed impellers.

The rotating region bodies around the impellers are automatically generated when [Set as Solid Region] is set for [Rotating Region Settings method] on [Analysis Condition]/[Fluid Analysis]/[Analysis Considering Rotation (MRF)].

Generating the mesh by [Run mesher] command creates two rotating regions [Impeller1_MRFAuto] and [Impeller2_MRFAuto].

 

-Model

 

 

-After generating meshes

Specific mesh size is not defined for the Rotating regions and impeller bodies. Mesh sizes are automatically calculated for them.

When specifying the mesh size for the rotating region, mesh sizes must also be specified for the impeller bodies.

See [How to Set Analysis Condition][Fluid Analysis][Analysis Considering Rotation (MRF)]], [Technical Note][Analysis Considering Rotation (MRF)] for the details.

Body Attribute and Material Setting

Body Number/Type

Body Attribute Name

Material Name

1/Solid

Impeller1

104_Stainless_steel *

2/Solid

Impeller2

104_Stainless_steel *

3/Fluid

Fluid

100_Water *

4/Solid

shaft

104_Stainless_steel *

(*) Available from the material DB.

Boundary Conditions

No modification from default setting.

Results

The vectors of the flow velocity distribution are shown below. Because there are no baffles, the entire tank is rotating.

 

 

Displaying [Table] > [Torque on Wall Face [N*m]] shows the wall torque for each impeller.

In this case the torque is relatively small, about -0.16 N*m, due to entire tank rotation.

Multiply this torque by the angular velocity to get the shaft power (P = torque on wall face * angular velocity).