Home / Examples / Thermal Analysis [Watt] / Example 31: Heat Dissipation analysis using a thermal network model (DELPHI model)
Example 31: Heat Dissipation analysis using a thermal network model (DELPHI model)

General
-
Create and analyze a DELPHI thermal network model from a detailed model (IC + board + simplified mold).
-
Use the Femtet Macro Appication 41 [Deriving a DELPHI Model (1D Thermal Analysis Model) Using the Femtet Macro] to generate the thermal network.
Refer ( https://www.muratasoftware.com/en/products/case/watt11/ ) and download macro.
-
Add 3D heatsink model to the board model generated by thermal network macro, then perform Thermal and Thermal-Fluid analyses.
-
Unless specified in the list below, the default conditions are applied.
-
Results will vary depending on Femtet version and the PC environment.
Analysis Model Download
-
Project file Download (Save the project file before open. Femtet 2026 or later is required.)
Analysis Space
|
Item |
Subject |
|
Analysis Space |
3D |
|
Model Unit |
mm |
Analysis Condition
1- DetailedModel: Detailed model
2- DELPHI_Mode: Thermal network mode
3- DELPHI_Model + Heatsink: Thermal network + heatsink assembly
|
Items |
Subject |
|
Solver |
Thermal Analysis [Watt] |
|
Analysis Type |
Steady-state analysis |
|
Analysis Options |
None |
|
Mesh size |
0.3[mm] |
4- DELPHI_Model + Heatsink Fluid: Thermal network + heatsink assembly with Fluid analysis
|
Items |
Subject |
|
Solver |
Thermal Analysis [Watt], Fluid Analysis [Bernoulli] |
|
Analysis type. |
Steady-state analysis |
|
Analysis Options |
Buoyancy External Flow Automatic Fluid Domain Creation |
|
Mesh size |
0.3[mm] |
Graphical Objects
1- DetailedModel: Detailed model
IC, board and Mold are defined as box solid bodies. Heat source is specified to the body attribute of the Mold.
Five surface boundary conditions - Top_inner, Top_outer, Sides, Bottom_inner, Bottom_outer - are applied to emulate nodes of the thermal network model.
Coefficient of Heat Transfer: 25[W/m2/deg] is specified for each boundary condition.

2- DELPHI_Mode: Thermal network mode
Prepare a Box solid model with the same dimensions as the DetailedModel, and sheet bodies for Top_inner and Top_outer sized 4 mm x 4 mm.
When the two sheet bodies are used to split the top and bottom faces of the box solid by [Segment Face], the top face is divided into faces corresponding to Top_inner and Top_outer, and the bottom face is divided into faces corresponding to Bottom_inner and Bottom_outer.
The two created sheet bodies are no longer needed and are removed.
Assign the body attribute ThermalNetworkModel to the solid and apply the same five boundary conditions to the faces as in from detailed model.

3- DELPHI_Model + Heatsink: Thermal network + heat sink assembly
Model obtained 3D heatsink to the thermal network model from 2-DELPHI_Mode.

4- DELPHI_Model + Heatsink Fluid: Thermal network + heat sink assembly with Fluid analysis
Perform Fluid analysis with the model 3-DELPHI_Model + Heatsin. The fluid domain is created automatically by using [automatic fluid creation] option in the analysis settings.
Body Attribute and Material Setting
|
Body type |
Body attribute name |
Material Name |
|
Solid |
IC |
Si |
|
Solid |
Mold |
Mat_Mold |
|
Solid |
Board |
Mat_Board |
|
Solid |
ThermalNetworkComponet |
Mat_Board*1 |
|
Solid |
Heatsink |
Al*2 |
*1 Material constants of the thermal network model are not used in the analysis, so any values are acceptable.
*2 Available from the material DB.
Additional settings in the Body Attribute tab are as follows.
|
Body attribute name |
Tab |
Setting |
|
IC |
Heat Quantity |
1 [W] |
|
ThermalNetworkComponet |
Thermal Network Model |
Internal Node Settings IC 1 [W]
Resistance value settings See Buckling Analysis. |
Boundary Conditions
1- DetailedMode: Detailed model
2- DELPHI_Mode: Thermal network mode
Sets or gets heat transfer coefficient [W/m2/deg].
|
Boundary condition name |
Tab |
Boundary Condition Type |
Subject |
|
Top_inner, Top_outer, Sides, Bottom_inner, Bottom_outer |
Thermal |
Heat transfer/Convection |
Coefficient of Heat Transfer: 25 [W/m2/deg] Room Temperature: 25 [deg] |
3- DELPHI_Model + Heatsink: Thermal network + heat sink assembly
Set Bottom_inner, this is the contact face between heatsink and thermal network, to [Measuring Terminal /Thermal Circuit External Node] boundary condition as non-thermal boundary , and assign Coefficient of Heat Transfer of 25 [W/m2/deg] to the other faces.
Top_inner, Top_outer, Sides, and Bottom_outer are also external thermal network nodes. Thermal boundary condition can be applied. See Thermal Network Model for the details.
Apply [Outer Boundary Condition] to the heatsink surface.
|
Boundary condition name |
Tab |
Boundary Condition Type |
Subject |
|
Bottom_inner |
Thermal |
Measuring Terminal /Thermal Circuit External Node |
|
|
Top_inner, Top_outer, Sides, Bottom_outer, |
Thermal |
Heat transfer/Convection |
Coefficient of Heat Transfer: 25 [W/m2/deg] Room Temperature: 25 [deg] |
|
Outer Boundary Condition |
Thermal |
Heat transfer/Convection |
Coefficient of Heat Transfer: 25 [W/m2/deg] Room Temperature: 25 [deg] |
4- DELPHI_Model + Heatsink Fluid: Thermal network + heat sink assembly with Fluid analysis
Set Bottom_inner, this is the contact face between heat sink and thermal network, to [Measuring Terminal /Thermal Circuit External Node] boundary condition, and assign Coefficient of Heat Transfer of 25 [W/m2/deg] to the other faces.
Because no thermal boundary is set at the fluid interfaces, apply [Measuring Terminal /Thermal Circuit External Node] boundary condition to Top_inner, Top_outer, Sides, Bottom_inner, Bottom_outer. See Thermal Network Model for the details.
Apply [Outer Boundary Condition] to the heat sink surface.
|
Boundary condition name |
Tab |
Boundary Condition Type |
Subject |
|
Top_inner, Top_outer, Sides, Bottom_inner, Bottom_outer |
Thermal |
Measuring Terminal /Thermal Circuit External Node |
|
Results
Use the Femtet Macro Appication 41 [Deriving a DELPHI Model (1D Thermal Analysis Model) Using the Femtet Macro] to generate the thermal network.
Refer ( https://www.muratasoftware.com/en/products/case/watt11/ ).
In this example, the DELPHI model was created using a single boundary condition set on the Top_inner, Top_outer, Sides, Bottom_inner, Bottom_outer ( =25 [W/m2/deg]).
Click the macro's Execute All button to run the calculation. Results appear in the [DELPHI Thermal Resistance] and [Model Evaluation] tabs.
[DELPHI Thermal Resistance] tab Thermal Resistance (K/W)
| IC | Top_inner | Bottom_inner | Sides | Top_outer | Bottom_outer | |
| IC |
- |
12.88364068 |
145.4898931 |
2157479.357 |
136.7477651 |
408.2638222 |
| Top_inner |
sym |
- |
1e+12 |
1e+12 |
1454.280725 |
1e+12 |
| Bottom_inner |
sym |
sym |
- |
1e+12 |
4359.860668 |
974.0340491 |
| Sides |
sym |
sym |
sym |
- |
173.0146664 |
402.8651498 |
| Top_outer |
sym |
sym |
sym |
sym |
- |
56.44448576 |
| Bottom_outer |
sym |
sym |
sym |
sym |
sym |
- |
[Model Evaluation] tab Temperature [deg]
| IC | Top_inner | Bottom_inner | Sides | Top_outer | Bottom_outer | |
| Detailed Model |
249.72792532543 |
247.921488257655 |
228.089580671191 |
154.434796690167 |
179.343530034228 |
173.248554438818 |
| DELPHI Model |
250.767836010127 |
248.996691339616 |
228.912521268167 |
154.06786507139 |
179.37489577453 |
173.117731534893 |
The result is shown below.
1- DetailedModel: Detailed model
Temperature result is shown below. In the DetailedModel, temperature gradients occur across each boundary surface.
The DELPHI model ignores these gradients and evaluates each surface by a single representative temperature.
The average temperature on each boundary roughly matches the temperature results shown in the macro's [Model Evaluation] tab.

2- DELPHI_Mode: Thermal network mode
Apply the heat resistance (K/W) results from the macro's [DELPHI Thermal Resistance] tab to the ThermalNetworkModel body attribute > [Thermal Network Model] tab > [Resistance value settings].
If the macro results are saved as CSV, they can be imported directly using the Import button. For the details, please refer to [Body Attribute] > Thermal Network Model Tab.
Calculation results of the thermal network model can be confirmed in the table [Thermal Network Model Information].
The thermal network model evaluates each boundary condition temperature of the detailed model as a single external node.
The table shows temperatures of internal nodes and each external node (boundary condition). External node values closely match the average temperature on the corresponding boundary surfaces in the detailed model.
The same temperature results as the macro's [Model Evaluation] tab (Temperature [deg]) are obtained.

3- DELPHI_Model + Heatsink: Thermal network + heatsink assembly
The thermal network model information and heatsink temperature results are shown below.
In contour view, the thermal network is not shown but the heatsink results are displayed.
Bottom_inner (approx. 122.28 deg) and the heatsink top have nearly the same temperature, with a gradient forming from the top into the heatsink.
Compared to result 2-, the absolute heat flow through Bottom_inner increased (-0.08 -> -0.39. This indicates improved heat dissipation with the heatsink.
However, applying Coefficient of Heat Transfer of 25 [W/m2/deg] over the entire heatsink causes excessive cooling. Bottom_inner temperature drops by about 100deg C compared to result of 2-.


4- DELPHI_Model + Heatsink Fluid: Thermal network + heatsink assembly with Fluid analysis
Displaying thermal network model information and temperatures of the heatsink and fluid with velocity distribution.



Bottom_inner temperature is slightly lower than in 2-. This indicates the heatsink heat dissipation is analyzed more accurately than in 3-.