Home / Technical Notes / Magnetic analysis / External Circuit Conversion
External Circuit Conversion
If external circuit coupling is ON in the magnetic transient analysis, conversion for external circuit can be set up on the [Magnetic analysis tab].
Conversion is conducted as described below.
-
See [Example of External Circuit Conversion Setup] for the details.
Conversion Procedure
If conversion setting is ON, Femtet performs the following conversions automatically.
-
Conversion of input parameters for full model to those for partial model
The required input values in analysis are for partial model.
Once the values for full model are entered, Femtet will automatically convert them for partial model.
-
Conversion of output parameters for partial model to those for full model
The values given by analysis are for partial model. They are automatically converted to the values for full model and output to the results table.
Conversion of Input Parameters
The values of input parameters of the external circuit for full model are converted for partial model as listed below.
Parameters not listed here will not be converted.
|
Component Name |
Parameter |
s: Number of Series |
p: Number of Parallels |
|
Voltage source |
Voltage (Amplitude) |
V/s |
- |
|
Voltage of the user-defined waveform table |
V/s |
- |
|
|
3-phase voltage source |
Voltage (Amplitude) |
V/s |
- |
|
Voltage of the user-defined waveform table |
V/s |
- |
|
|
DC voltage source |
Power voltage |
V/s |
- |
|
Current source |
Current (Amplitude) |
- |
I/p |
|
Current of the user-defined waveform table |
- |
I/p |
|
|
3-phase current source |
Current (Amplitude) |
- |
I/p |
|
Current of the user-defined waveform table |
- |
I/p |
|
|
DC Current Source |
Current Value |
- |
I/p |
|
FEM Coil |
Resistance |
R/s |
R*p |
|
Leakage inductance |
L/s |
L*p |
|
|
Resistor |
R |
R/s |
R*p |
|
Resistance of the user-defined waveform table |
R/s |
R*p |
|
|
Inductor |
L |
L/s |
L*p |
|
Capacitor |
C |
C*s |
C/p |
|
Diode |
Saturation Current |
- |
Is/p |
|
Coefficient of Emission |
NF/s |
- |
Conversion of Output Parameters
The values of output parameters of the external circuit for partial model are converted for full model as listed below.
Parameters not listed here will not be converted.
|
Output Value |
s: Number of Series |
p: Number of Parallels |
|
Circuit current |
- |
I*p |
|
Voltage drop in the circuit |
V*s |
- |
|
Induced voltage of coil |
V*s |
- |
|
Interlinkage magnetic flux of coil |
Φ*s |
Φ*p |
|
Self inductance |
L*s |
L/p |
|
Mutual inductance |
L*s |
L/p |
-
A parameter below will not be converted as it is used within analysis model, not for external circuit.
Input current of coil