CAE Software【Femtet】Murata Software Co., Ltd.
General
Heat dissipation of an IC on the substrate by the forced convection is solved by the transient analysis.
The temperature distribution and the heat flux vectors are solved.
Unless specified in the list below, the default conditions will be applied.
Obtain this session's project file. (Save the project file before open)
Item |
Setting |
Analysis Space |
3D |
Model Unit |
mm |
Item |
Setting |
Solver |
Fluid Analysis [Bernoulli] Thermal analysis [Watt] |
Analysis Type |
Transient Analysis |
Laminar Flow/Turbulent Flow |
Select Turbulent Flow |
Meshing Setup |
General Mesh size: 5 [mm] |
The Transient Analysis tab is set up as follows. The total number of steps is 20. The timestep is 60 seconds.
Therefore, the temperature distributions for 20 minutes are solved.
Tab |
Setting Item |
Setting |
||||||||
Transient Analysis |
Table |
|
||||||||
Initial Temperature |
25[deg] |
To shorten the calculation time, set the large value for convergence judgment. The settings on the high-level setting tab are as follows.
Tab |
Setting Item |
Setting |
High-Level Setting |
Nonlinear Analysis |
Convergence Judgment (Heat): 1 x 10^-3 |
The model is a box solid body. The material is Air (000_Air). The boundary conditions of inlet and outlet are set on the left edge and the right edge respectively.
The slip wall outer boundary condition is applied to the top and bottom edges where the boundary condition is not set.
The substrate (VOL1) and IC (VOL2) are solid bodies.
Body Number/Type |
Body Attribute Name |
Material Name |
Mesh Size |
0/Solid |
VOL1 |
006_Glass_epoxy * |
0.2 |
1/Solid |
VOL2 |
001_Alumina * |
0.2 |
2/Solid |
Air |
000_Air(*) |
– |
* Available from the material DB
Specific heat is set as follows since it is not set in the material database.
Material Property Name |
Tab |
Setting |
001_Alumina |
Specific Heat |
800 [J/kg/deg] |
IC (VOL2) is set as follows on the Heat source tab.
Body Attribute Name |
Tab |
Setting |
VOL2 |
Heat Source |
1W |
Boundary Condition Name/Topology |
Tab |
Boundary Condition Type |
Setting |
In/Edge |
Thermal Fluid |
Inlet |
Forced Inflow Inflow Temperature : 25[deg] |
Out/Face |
Thermal Fluid |
Outlet |
Natural Outflow |
Outer Boundary Condition |
Thermal Fluid |
Slip wall |
– |
The figure below shows the temperature distribution after 1[min] = 60[s], 5[min] = 300[s], and 20[min] = 1200[s]
The maximum and minimum values of the temperature scale are 61[deg] and 25[deg] respectively.
For easy viewing of the temperature distributions of the substrate and the IC, the ambient air field is hidden by right-clicking the air body and selecting [Hide Body Field].
The temperature is rising gradually.
1[min] | |
5[min] | |
20[min] |
The temperature change at the coordinates (0, 0, 3) which is above the IC is plotted as follow.
Again, it can be observed that the temperature is rising gradually.