Example15 Radiation and Cooling of IC inside a Case by Natural Convection (Closed Space and Open Space)

General

  • An IC is encased on a substrate. The heat dissipation of the IC by radiation and natural convection is solved by the steady-state analysis.

  • Natural convection in the closed space of the case and radiation and natural convection in the open space outside the case are solved at the same time.

  • In [Example 9: Cooling of IC inside the Case by Natural Convection (Closed Space and Open Space)], natural convection alone is taken into account but not radiation.
     

  • The temperature distribution and the heat flux vectors are solved.
     

  • Unless specified in the list below, the default conditions are applied.
     

 

Analysis Space

Item

Setting

Analysis Space

3D

Model Unit

mm

 

Analysis Condition

Item

Setting

Solver

Fluid analysis [Bernoulli]

Thermal analysis [Watt]

Analysis Type

Fluid analysis: Steady-state analysis

Thermal analysis: Steady-state analysis

Laminar Flow/Turbulent Flow

Select Turbulent Flow

Option

Select Take Buoyancy into Account (Natural Convection)

Layer Mesh Setting for Wall Surface (General Settings)

Parameters for Automatic Creation

Expected Temperature Difference: 50[deg]

Meshing Setup

General Mesh size: 10 [mm]

Model

The model is a box solid body. The material is Air (000_Air).

Set natural inflow/outflow to the outer boundary condition of Inlet/Outlet.

The substrate (VOL1), the IC (VOL2), and the case (CASE) are solid bodies.

 

Setting of Body Attributes, Materials, and Mesh Sizes

Body Number/Type

Body Attribute Name

Material Name

Mesh Size

0/Solid

VOL1

006_Glass_epoxy *

2.0

1/Solid

VOL2

001_Alumina *

2.0

2/Solid

Air

000_Air *

3/Solid

CASE

001_Al *

4.0

* Available from the material DB

 

IC (VOL2) is set as follows on the Heat Source tab.

Body Attribute Name

Tab

Setting

VOL2

Heat Source

1W

Thermal Surface

Emissivity:
Select Specify on each body attribute

0.85

Boundary Condition

Boundary Condition Name/Topology

Tab

Boundary Condition Type

Setting

Outer Boundary Condition

Fluid-Thermal

Inlet/Outlet

Natural Inflow/Outflow

Inflow temperature: Use ambient temperature (25[deg])

Thermal

None

Radiation type: Surface-to-surface (accuracy prioritized)

 

Results

The radiation surface is automatically set to the case surface, the substrate surface, and the IC surface.

To check the setting, the emissivity of the case surface and the radiation rate of the substrate and the IC are shown.

From the diagram, it is confirmed that the emissivity is 0.8 and 0.85 respectively.

 

The temperature distribution is shown below. For comparison, the result of Example 9 (without radiation) is shown as well.

The cross section at x=0 is displayed.

It can be seen that the cooling effect is higher and the temperature of the IC is lower when the radiation is taken into account compared to the case where only natural convection is taken into account.

 

 

Example 9: Natural convection only

Example 15: Natural convection and radiation