CAE Software【Femtet】Murata Software Co., Ltd.
General
The magnetic field generated by a loop coil is analyzed.
The vectors and the directivity of the magnetic field are solved.
Unless specified in the list below, the default conditions will be applied.
Item |
Settings |
Analysis Space |
3D |
Model unit |
mm |
Item |
Settings |
Solvers |
Magnetic Field Analysis [Gauss] |
Analysis Type |
Static analysis |
Options |
N/A |
A solid body of loop coil is defined.
When you calculate the directivity, select open boundary as outer boundary condition.
Body Number/Type |
Body Attribute Name |
Material Name |
Mesh Size |
2/Solid |
Coil |
008_Cu * |
0.25 |
* Available from the Material DB
Body Attribute Name |
Tab |
Settings |
Coil |
Current |
Waveform: Constant Current: 1[A] Turns: 1[Turns] Direction: Loop Coil/Magnetic Field Direction: Magnetic Field Vector: X=0, Y=0, Z=1 |
Open boundary is set for the outer boundary condition.
Boundary Condition Name/Topology |
Tab |
Boundary Condition Type |
Settings |
Outer Boundary Condition |
Electric |
Open boundary |
|
The vectors of the magnetic field on XZ plane are shown below.
The chart below shows the directivity of the magnetic field. (θ: min 0.0[deg], max 180[deg], step 18)